ADSL IP DSLAM
73
5. MaxTxRate: 1024
6. MaxInterleaveDelay:16
Creating Alarm Profile
This section describes how to create an alarm profile.
Command: add alarmprof <profile name>
Argument List:
Parameter type Parameter
data-type and
field
Description
alarmprof name String, <= 32 The name of ADSL alarm profile.
Thresh15MinLofs Integer, 0 ~ 900 The threshold of the number of
“Loss of Frame Seconds” within
15 minutes performance data
collection period.
Thresh15MinLoss Integer, 0 ~ 900 The threshold of the number of
“Loss of Signal Seconds” within
15 minutes performance data
collection period.
Thresh15MinLols Integer, 0 ~ 900 The threshold of the number of
“Loss of Link Seconds” within 15
minutes performance data
collection period. (But only
ATU-C side)
Thresh15MinLprs Integer, 0 ~ 900 The threshold of the number of
“Loss of Power Seconds” within
15 minutes performance data
collection period.
Thresh15MinESs Integer, 0 ~ 900 The threshold of the number of
“Errored Seconds” within 15
minutes performance data
collection period.
InitFailureTrapenable enable / disable Enable or disable the Initial
Failure Trap. Default setting is
disable. (Only on ATU-C side)
Example: This example shows how to create an alarm profile named test.
IPDSLAM # add alarmprof test
(alarmprof-atuc)# 30 10 50 5 4 enable
(alarmprof-atur)# 30 2 2 5
ADSL Alarm Profile “test” content:
ATU-C:
Thresh15MinLofs: 30
Thresh15MinLoss: 10
Thresh15MinLols: 50
Thresh15MinLprs: 5
Thresh15MinESs: 4